ANROT Tutorial
ANROT RS485 / Modbus Poll Profiles
ModBus Poll profile files for quickly reading product-information and live IMU registers.
- rs485
- modbus
- tutorial
Recommended tool
Protocol Support
| Protocol / frame | Support | Scope of this tutorial |
|---|---|---|
| Modbus RTU | Supported | Uses .mbp profiles to read product information and IMU registers. |
ANROT UART binary (0x91, 0x62, 0x63) | Not applicable | RS485 Modbus uses register-based request/response and does not use these UART frames. |
| CANopen / J1939 | Not applicable | Use the CANopen or J1939 tutorials for CAN bus protocols. |
Use ModBus Poll 64-bit 9.9.2 to open the profiles below.
Download the profiles
Use case
These profiles are intended for maintenance and industrial bring-up work where RS485 / Modbus devices need to be checked quickly at the register level.
Usage notes
- Confirm that the device is really configured for the expected Modbus communication mode.
- For HI04-class products, verify that the final system is set to Modbus output before using these profiles.
- If no data is returned, check the slave ID, baud rate, parity, and USB-to-RS485 adapter first.